action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114Being India’s top autoclave manufacturer, we offer high-quality machines that are ISO, GMP, and CE certified for the strict sterilization needs of hospitals, pharmaceutical labs, and other critical environments. We have user-friendly autoclaves that require minimum maintenance and can be used in general or specialized laboratory sterilization procedures.
Our goal is to make sure every single one of our autoclave sterilizers meets the highest standards for effectiveness in the industry. They are designed for use in laboratories, clinics, hospitals, pharma research centers, tissue culture facilities, and agriculture, among others. Apart from having several standard models available on a pre-order basis, we also do custom design and manufacturing services according to client specifications, which may involve adding extra features to enhance versatility.
Bionics Consortium is ranked among the top Indian companies manufacturing autoclaves. We specialize in producing different types of autoclave sterilizers suitable for various sectors, including medical institutions such as hospitals and pharmaceutical research laboratories. Our machines can be used for multiple purposes because they serve both broad-spectrum uses as well as specific requirements; hence, they are easy to operate since they are user-friendly, require low maintenance costs, but are highly efficient when it comes to performance levels achieved during their functionality period. The different models offered by Bionics Consortium include vertical, front-loading double-door horizontal rotary dental plasma, among others, which all have option accessories that can be added on so as to make them more effective depending on what they will be serving.
Bionics Consortium is an established player within the autoclave manufacturers’ space, having ISO & CE certification-backed products that provide superior quality sterilization equipment across various industries like hospitals, medical labs, etc., where certain standards need to be met consistently throughout operations carried out there under different conditions ranging from normal usage up to extreme usage situations such as those encountered within agricultural environments. There are many different models available with special configurations and add-ons.
Features:
The autoclave, steam sterilizer, or sterilization machine is a sealed container used to achieve sterility or disinfection for utensils. It is performed at a temperature of about 121°C to 134°C for 15 to 20 min under a pressure range of approximately 45 psi to 50 psi. These autoclaves can kill viruses, spores, bacteria, and fungi that live on stored equipment by using confined pressures.
Most clinical laboratories use an autoclave/steamed sterilizer, which works by exposing items to steam pressure.
Autoclaves or steam sterilizers work using two main methods, which include gravity displacement and pre-vacuum sterilization. Some autoclaves use both methods together for better sterilization over the years.
When an item or material needs to be sterilized, it is placed into an autoclave, and the top of the equipment is closed. Then air is removed from the vessel in one of two ways: through vacuuming or subjecting it to reverse pressure. A vessel with steam uses a gravity displacement unit to force out air within it, hence creating a vacuum. Pre-vacuum design involves negative gauge readings being obtained before switching off the vacuum pump when air has been removed from the plane by the vacuum pump. Once the chamber has been purged of air content, it gets filled up with high-heat steam so as to raise the temperature further inside. At this point, constant flow of steam maintains a set temperature throughout the vessel until the required set temperature is achieved.
There are three phases of the process:
The heat involved in the autoclave sterilization process should be 121 °C, but some equipment or items may need up to 134 °C. Medical equipment requires a temperature range of 70-90°C, hence taking 3 to 4 minutes for sterilization, though if medical equipment has material, it can take up to 15-20 minutes.
The following are the parts of a typical laboratory autoclave: